Enraf-Academy Introduction Note

  • Users of Enraf-Nonius treatment devices must be trained in how to use the system properly and have the appropriate skills.
  • Any treatment instructions regarding treatment location, duration and strength require medical knowledge and should only be given by authorised doctors, therapists and health professionals. It is imperative that these instructions are followed.
  • Before using Enraf-Nonius equipment, read, understand and practice the instructions for use. Know the limitations and hazards associated with using the device. Also observe the precautionary and operational decals placed on the unit.

Electrotherapy (electrical currents)

Electrotherapy is the use of electrical energy as a medical treatment. Electrotherapy (or Electro Physical Agents – EPA’s) comprise a wide variety of treatment methods for several indications and conditions like electrical currents, short- and microwave and ultrasound. In this "Electrotherapy" section we limit the scope to electrical currents for therapeutics purposes. that is:

  • Interferential Currents
  • Biphasic Pulsed Currents (TENS)
  • Premodulated currents
  • Russian Stimulation
  • Micro Currents
  • High Voltage
  • Diadynamic Currents
  • Galvanic Currents
  • Faradic Currents

These current forms in Enraf-Nonius electrotherapy equipment are primarily designed for pain management, muscle stimulation and tissue regeneration.

Want to know more?

For more information please go to

Enraf-Nonius Electrotherapy Equipment

   

Enraf-Nonius
 
Enraf-Nonius

Endomed 482
Complete, easy-to-use, fast and the responsible choice for electrotherapy!
Leaflet Manual Youtube
   

Enraf-Nonius
 
Enraf-Nonius

Endomed 182
Cheapest professional device for interferential current (IFC) and tens
Leaflet Manual Youtube
   

Enraf-Nonius
 
Enraf-Nonius

Vacotron 460
Suction module: A valuable addition to the Endomed 482 or Sonopuls 492
Leaflet Manual

Electrotherapy Indications and Contra-Indications

 

Indications Electrotherapy

 

All

  • Pregnancy (do not apply anywhere over abdomen/pelvic region). Safety has not been established for the use of therapeutic electrical stimulation during pregnancy.

Pain Management

  • Symptomatic relief of chronic, intractable pain. Management of pain associated with post-traumatic or postoperative conditions.

Muscle Stimulation

  • Relaxation of muscle spasms
  • Prevention or retardation of disuse atrophy
  • Increasing local blood circulation
  • Muscle re-education
  • Immediate post-surgical stimulation of calf muscles to prevent venous thrombosis
  • Maintaining or increasing range of motion
  • Dysphagia

 

Contraindications Electrotherapy

 

Pain management

  • This device should not be used for symptomatic pain relief unless etiology is established or unless a pain syndrome has been diagnosed.
  • This device should not be used on patients with demand-type cardiac pacemakers.
  • This device should not be used over cancerous lesions.
  • Electrode placements that apply current to the carotid sinus region (anterior neck) must be avoided.
  • Electrode placements that apply current trans cerebrally (through the head) must be avoided.
  • Electrode placements that apply current trans thoracically (the introduction of electrical current into the heart may cause cardiac arrhythmias) must be avoided.

Muscle stimulation

  • This device should not be used on patients with demand-type cardiac pacemakers
  • This device should not be used over cancerous lesions
  • Electrode placements that apply current to the sinus carotid region (anterior neck) must be avoided (*)
  • Electrode placements that apply current trans cerebrally (through the head) must be avoided.
  • Electrode placements that apply current trans thoracically (the introduction of electrical current into the heart may cause cardiac arrhythmias) must be avoided.

Note (*) However, the application area for the treatment of Dysphagia is distant enough from the sinus carotis area, when the therapist follows the guidelines as described in the therapy book "Dysphagia (by H.C.A. Bogaardt SLP, PhD)"

 

Precautions and warnings Electrotherapy

 

Pain management

  • Benefits of TENS currents have not been established for pain of central origin.
  • This device is to be used as a symptomatic treatment for pain and has no curative value. Patients should be cautioned and their activities regulated if pain that would otherwise serve as a protective mechanism is suppressed.
  • The long-term effects of chronic electrical stimulation are unknown.
  • Safety has not been established for the use of therapeutic electrical stimulation during pregnancy.
  • Stimulation should not be applied over swollen, infected, or inflamed areas of skin eruptions e.g., phlebitis, thrombophlebitis, varicose veins, etc.
  • Isolated cases of skin rash may occur at the site of electrode placement following long-term applications. The irritation may be reduced by use of an alternate conductive medium or an alternative electrode placement.
  • Effectiveness of this treatment is dependent upon patient selection.
  • See also chapter 9 for general warnings and precautions.

Muscle stimulation

  • The long-term effects of chronic electrical stimulation are unknown.
  • Safety has not been established for the use of therapeutic electrical stimulation during pregnancy.
  • Stimulation should not be applied over swollen, infected, or inflamed areas of skin eruptions e.g., phlebitis, thrombophlebitis, varicose veins, etc.
  • Adequate precautions should be taken when treating individuals with suspected or diagnosed heart problems, or epilepsy.
  • Caution should be used when there is a tendency to hemorrhage following acute trauma or fracture.
  • Caution should be used following recent surgical procedures when muscle contraction may disrupt the healing process.
  • Caution should be used over the menstruating uterus.
  • Caution should be used over areas of the skin which lack normal sensation.
  • Some patients may experience skin irritation or hypersensitivity due to electrical stimulation or electrical conductive medium. The irritation can usually be reduced by using an alternative conductive medium, or alternate electrode placement.

Please consult the Instructions for Use for more information on indications and contra-indications and for warnings and recommendations.

The above indications and contra-indications originated from the 4-Series Operating Instructions EN 1498751-47.

Downloads    |   Legal notices     |     Acknowledgement     |     Privacy policy     |     Contact     | Member of Zimmer Medical Group

We use cookies

We use cookies on our website. Some of them are essential for the operation of the site, while others help us to improve this site and the user experience (tracking cookies).
You can decide for yourself whether you want to allow cookies or not.

Please note that if you reject them, you may not be able to use all the functionalities of the site.